iSWAB-RNA-v2
iSWAB-RNA-v2
iSWAB-RNA-v2
iSWAB-RNA-v2

Other presentations

ISR2-T-1200-R iSWAB
iSWAB™-RNA-v2 Collection Device Rack
SEE PRODUCT
ISR2-T-1200 iSWAB RNA v2
iSWAB™-RNA-v2 Collection Device Bag
SEE PRODUCT

Benefits

benefits Icon

Maintaining RNA stability and protecting it from degradation is a significant challenge, while current RNA stabilization methods such as PAXgene, Tempus, RNAgard or dry blood spots require invasive blood collection resulting in low compliance. The need to collect blood results in a very limited shelf life, forcing labs to invest in cold storage infrastructure or commit resources to immediate sample processing. Other options for non-invasive collection also suffer from short shelf life storage as well as low quality and unusable RNA. Mawi DNA Technologies developed the iSWAB™- RNA-v2, the only non-invasive technology for the collection and extended room temperature stabilization of high-quality RNA from oral samples with applications in microarray and sequencing-based gene expression profiling and transcriptomics.

Product detail

Features

  • Swab-free sample transport: Decrease sample processing time without compromising sample integrity.
  • Increase process efficiency: Extended shelf life stability (up to 4 weeks at room temp, several years at -20 C and -80 C), reduced processing time, and minimal storage footprint.
  • High-quality RNA for downstream applications such as RT-PCR, Microarray and RNA-seq for gene expression analysis.
  • Room temperature stable: Reduce sample storage and transport costs by eliminating cold chain requirements.
  • Self-collection or assisted collection in less than 2 minutes: Suitable for all population segments including infants, toddlers, and the elderly.
  • Traceable and reliable chain of custody: LIMS-compatible unique bar­codes included on each collection device for efficient traceability and storage purposes.
  • Scalable and easy to process: Manual and automation-friendly sample processing.

iSWAB™-RNA-v2 Collection Kit

Applications

Product Common Name: iSWAB™-RNA-v2 Kit

Product Full Name: iSWAB™-RNA-v2 Collection Kit

Part Number: iSWAB™-RNA-v2

Units: 1.0 mL

Includes:
1 iSWAB™-RNA-v2 Device
4 Sterile Applicators
Plastic “biohazard” bag w/ absorbent pad
Extra barcode label (for lab use only)
“Exempt Human Specimen” label
Outer box (used to mail sample back)

*The products shown contain the CE Mark and are approved for IVD use in countries recognizing this standard. In the USA, products are designated For Research Use Only and not for use in diagnostic procedures and will be labeled accordingly.

Devices only for collecting human RNA samples via buccal cells.
Transcriptomics, Gene Expression: qPCR and RNA-based sequencing (RNAseq) , microarray, Northern Blot, Nuclease protection assays, cDNA library construction, Mass spectrometry, ELISA, Western blotting, tissue biopsy stabilization.

Product Description

The iSWAB™-RNA-v2 device is a non-invasive technology for the collection, concentration, and stabilization of intact buccal cells or any mammalian cells collected with a swab or cytobrush allowing for real time ambient stabilization of total RNA from the point of collection to processing. The design of the iSWAB™ collection device allows for the maximum release of collected samples from multiple swabs or brushes into a single device, to achieve a more concentrated sample. Self-collection or assisted collection can be achieved in less than 2 minutes and is suitable for all population segments including infants, toddlers, and elderlies.

Intended Use

iSWAB™-RNA-v2 Collection Kit is a RNA sample collection device for the collection, stabilization, concentration, transport and storage of RNA samples. It is a non-invasive swab-based sampling applicator and is intended to be used for sample collection from various sample types including intact buccal cells and/or any mammalian cells collected with a swab or cytobrush.

Indication for Use (from IFU)

The iSWAB™-RNA-v2 device allows for the non-invasive collection, concentration, and stabilization of intact buccal cells and/or any mammalian cells collected with a swab or cytobrush. Allows for real time ambient stabilization of total RNA from the point of collection to processing. The iSWAB™-RNA-v2 maintains RNA stability and protects RNA from degradation. The device allows extended shelf life stability (up to 4 weeks at room temp, several years at -20 C and -80 C), reduced processing time, and minimal storage footprint.

Storage and Stability

Pre-collection: 18 months from date of manufacture between 15-30° C.
Transport temperature, post-collection: 15-30° C.
Sample stability and storage, post-collection: viable cells are stabilized for up to 4 weeks at at 15-30° C; if longer storage time is required, collected samples can be stored at -20 to -80° C for several years.

Resources

Product
iSWAB-RNA-v2
Pre-Collection
Time Temp (C)
18 mo. DOM 15-30
Transport
Temp (C)
15-30
Analyte
Type
Total RNA
Post Collection
Time Temp (C)
4 weeks 15-30
Cryo Storage
Temp (C)
-20- to -80
Attributes iSWAB™-RNA-v2
Sample Buccal
Use Mammalian RNA
# Swabs 4
Collection Volume 1.0 mL
Nucleic Acid Yield (μg) varies**
Storage and Transport temperature RT
Shelf Life Stability 18 months
Post-collection Stability 4 weeks
Capability to concentrate sample Yes
Suitable for all population segments Yes
Automation friendly Yes
Liquid Sample Yes
Barcoded Included
Compatible Assays Illumina Stranded Total RNA Prep w/ Ribo-Zero (Illumina, Cat. # 20040525, 20040529), Human EGFR In-Cell ELISA Kit (abcam, Cat. # ab126419)
Applications Illumina Stranded Total RNA Prep w/ Ribo-Zero (Illumina, Cat. # 20040525, 20040529), Human EGFR In-Cell ELISA Kit (abcam, Cat. # ab126419)

WARNING AND PRECAUTIONS

For external use and single use only. DO NOT drink, touch, or remove the buffer from the device. Do Not use if device is broken, leaking, or visibly damaged. These products should only be used in accordance with the instructions provided. Avoid eye contact with the liquid in the device. IF IN EYES: Rinse cautiously with water for several minutes. IF INGESTED: Call POISON CENTER. Rinse mouth. Not a Hazardous Combustion Product. Device cap can be a choking hazard. Do not ingest. Refer to SDS.